Please click the link below to install the XGPC Ver 1.9.1
(If you can not access to this link by a click, please copy and paste the link to the "address bar")
XGPC_V1.9.1_ENG_BUILD2015-08-08.zip
XGPC v1.9 New Feature
This section provides information that has been added to the new release of XGPC. This includes the following:
- Support the X8-M Series A FRN9.
- Add RPM (Revolutions Per Minute) feature into HSC of Special Function Registers.
- The Ethernet TCP Connection is resets if there is any garbage received packet
- Added a feature "Mask 7 Bits of Received Character" for ASCII/Binary driver.
- Added an option SR2.2.8, "Keep a bit in Pre-1st Pass of OUT instruction (Compatible with Self-Holding)".
- Added an option SR2.2.0, "No rounding in MOV instruction".
- Added X8EXP Read or Write command to Expansion I/O on Xbus.
- Added a warning option for duplicated operand of OUT instruction.
- Added a large icon option for toolbar
- Added zoom-in and zoom-out by mouse wheel
- Added update time in trend property
- Added RNM and SCU2 in I/O module.
- Added RNM status dialog in Project tree.
- Added SCU2 status dialog in Project tree.
- Changed to binary operand format for MOVM, AND, OR, and XOR instruction.
- Added Short-key for Changing to reference subroutine in Call instruction.
- Added a data table creating function for extended PID data table.
- Added a subroutine creating function for HSC, PIT, and EII special function register.
- Added a address replace for data table type and number.
- Modified to enter a file name in the new project dialog.?(XGPC v1.9.1)
- Run the program as an administrator has enabled.?(XGPC v1.9.1)
- Fixed image size for high-definition DPI.?(XGPC v1.9.1)
- Allow multiple creation for ladder program and data tables.?(XGPC v1.9.1)
This section provides information on issues that have been resolved with the latest release of XGPC. This includes the following:
- Fixed that PTO.x.OperationFrequency was not updated to zero after Homing Done before Idle
- fixed PTO Homing Error Code
- Corrected Clear Data Table feature.
- Corrected CPU reboot continuously.
- Corrected Maximum number of NX-Plus Master MSG
- Corrected Expansion I/O update routine while there are any power failed RJ2EB module.
- Corrected missing count up for Data Sync error
- Corrected LIM instruction.
- Corrected CPU Fault while going to Executing mode if the Expansion I/O module needs much time to configure the configuration.
- Fixed a Transmit Socket MSG Length.
- Fixed a title name update for online
- Fixed a multiline comment in Comment import
- Fixed a wrong Trend monitoring when PLC is going to online
- Fixed a wrong location of err operand for COPT instruction
- Fixed a INV instruction. If INV instruction is in s branch, it did not work correctly.
- Corrected a maximum element number of the NX-Alpha Command in the MSG instruction.?(XGPC v1.9.1)
- Fixed that does not find Done, Error, etc. in the Find dialog.?(XGPC v1.9.1)
- Fixed an error when you paste more data tables than the maximum number of tables.?(XGPC v1.9.1)
- Fixed a problem beyond the maximum number for the multibytes character in the project tree.?(XGPC v1.9.1)
|